控件[tem_25_34]渲染出错,Source:未将对象引用设置到对象的实例。
首页    常规岩心分析设备    AMS-900超声波分离器    AMS-900 ACOUSTICALLY MONITORED SEPARATOR

AMS-900 ACOUSTICALLY MONITORED SEPARATOR

AMSTM-900 ACOUSTICALLY MONITORED SEPARATOR


A 20,000 psi dual-bore mechanical separator equipped with an ultrasonic transducer for detection of liquid-liquid/gas-liquid interfaces.  The relative proportion of effluent is sensed by a sound reflection technique that utilizes an acoustic pulse triggered at the bottom of the measurement bore.  The pulse travels upward through the denser fluid occupying the lower section and is reflected by the fluid interface.  The fluid volume is determined by the comparison of the travel time of the reflected pulse from the fluid interface and the simultaneous reflected pulse from a target at a known height thus performing a continuous calibration allowing the system to determine precise volumes even in varying density situations such as temperature and pressure variation.  The AMS-900 can also be used for the measurement of the acoustic velocity of various fluids such as brines and crude oils at reservoir condition. 

 

The AMSTM-900 design allows fluid collection and separation to occur in one bore.  This first bore is in constant communication, at top and bottom, with  the second, measurement bore.  Measurement accuracy is dependent upon the separator tube being maintained in a true vertical position.  System includes a PC based pulsar/receiver device coupled  with a Windows based operating software allowing for ease of use, troubleshooting capability and error checking. When integrated into a Core Flood system, the pulser/receiver device can be connected to the host computer via a USB port. 



Standard Model Specifications: 

Separator and Measurement Bore: 0.500" 

Overall Height: approx. 90 cm 

Material:  Hastelloy C, 316 Stainless Steel & Titanium Transducer assembly 

Transducer, Natural Frequency: approx. 2MHz 

Measureable Volume: 100cc 

Maximum Operating Pressure: 20,000 psig (Approx. 1400Bar) 

Maximum Operating Temperature: 300℉ (150 Deg C) 

Resolution, 0.01cc 

Accuracy, +/- 0.01cc 

     

Scope of Supply 

   1  Operations Manual 

   1 Tool and Accessory Kit for AMS-900-20K 

   1 Separator, twin column, with base 

   1 Manual set of valves 

   1 Laptop PC with operating software and onboard oscilloscope 

     USB Pulsar/Receiver Unit 

 

   Options Available on Request: 

   1  Two Years Spare Parts consisting of: 

      O-ring Seal Kit, 2 each 

      Calibration rings, 2 each 

      Set of fittings 

     

   1  Air Operating Control Valves 

    Set of Two (2) 3-way Air operated valves for computer automation plus plumbing 